Open topic with navigation
Prospect/Student Import
Files from any supplier of Prospect/Student data can be used, however
the data MUST be in the correct
Import Layout to be imported into
CAMS. Validation Rules will also
be applied during the import process. When the data is ready to be imported,
you must first create an Import Job before
defining the Prospect/Student Import Parameters.
Note:
Because the import process can be lengthy and locks the Admissions Module
while processing, it is strongly recommended that this data be imported
during off-peak hours when users are not in CAMS Enterprise.
To define Prospect/Student Import Parameters:
- Click Tools
>Import >Admissions >Prospect/Student Import. The
Prospect/Student Import window
opens.
- Select the appropriate Import Job, required. The Import
Job is created in the Prospect/Student Import Job window.
Note: Once a job has been completed it will no longer display in the Import Job field. If using an import job generated by ISIR records, be sure the import process in ISIR Direct is completed before proceeding.
- Select the High School Code Type and College Code Type that is assigned to High Schools and Colleges in your system.
Note: High School Code Types and College Code Types must be assigned to Admissions >Lookups >High School (and College Names) in order for CAMS to import the test, high school, and college information from the import file.
- Determine the Matched
Record Behavior (If a match is found):
- CAMS
Dominant - Data in the existing record will NOT be changed with
the data in the imported record.
- Import
Dominant - Data in the import record will replace the data
in the existing record.
Click
here to learn how matches are determined.
- Determine the Unmatched
Record Behavior (If a match is NOT found):
- Create
New Records - Check this to create new records during the import
process.
- Insert
To - Select either Prospects
or Students to define whether
new records will be prospect or student records.
- Activity - If appropriate, Select A Group
of activities to be applied to all new records. Groups of activities
are defined in Admissions >Lookups
>Define Letter Sequences. The Starting
Date for the sequence defaults to the current date but may
be changed if necessary. If Students
is select in Insert To, the starting Term
may also be defined.
- Expected
Entrance Term - Select the Expected Entrance Term for this group of Prospects or Students. The Term entered here will be the Term used in the student's first Status record which is automatically generated upon creating the student record when either importing as Students or when the Prospect record is loaded into Student.
- Prospect/Applicant
Status - If appropriate, a Prospect/Applicant Status (Prospect/Applicant
Status reference table) may be defined for all new records.
- Address
Type - CAMS requires at least one active address for all
records, select the Address Type to apply. This type should reflect
the type of address in the data set being imported.
- Student
Type - If Students is selected in Insert To, select the
appropriate Student Type. This is not available if Prospects is selected
in Insert To.
- Campus - If a Campus is selected, it will populate in the Campus field in
the Prospect(s) or Student(s) created by the import.
- Applied
For Term - If an Applied For Term is selected, it will populate
in the Applied For Term in the Prospect(s) or Student(s) created by
the import.
- Click Next
to initiate the import process. CAMS opens the New
Records window. These are individuals who do not have an existing
record in CAMS. If there are no records in the data grid, then all
records in the data set already exist in CAMS. Records default to
be imported, but you can either click Select/Deselect
All, or click the Import
check box to individually select/deselect records to import.
Note: If the data
is not in the correct format, or if the data cannot be properly validated,
or if there are duplicate records in the data set, CAMS displays a message
stating why the import cannot continue.
- The New Records window opens if there are no errors. These are individuals who do not have an existing record in CAMS. If there are no records in the data imported, you can either click Select/Deselect All, or click the Import check box to individually select/deselect records to import.
- Click Next
on the New Records window to continue to the Exact Matched Records
window. These are individuals who have records that exactly match
the import data set. If there are no records in the data grid, then
no records in the data set have an exact match. Records default to
be imported, but you can either click Select/Deselect
All, or click the Import
check box to individually select/deselect records to import. Imported
records will only be updated based on the Matched Record Behavior
defined in the Prospect/Student Import Parameters.
- Click Next
on the Exact Matched Records window to continue to the PartialExact
Matched Records window. These are individuals who have
records that have a partial exact match to the import data set. If
there are no records in the data grid, then no records in the data
set have a partial exact match. Records default to be imported, but
you can either click Select/Deselect
All, or click the Import
check box to individually select/deselect records to import. Imported
records will only be updated based on the Matched Record Behavior
defined in the Prospect/Student Import Parameters.
- Click Next
on the Partial Exact Matched Records window to continue to the Fuzzy
Matched Records window. These are individuals who have
records that are a fuzzy match in the import data set. If there are
no records in the data grid, then no records in the data set have
a fuzzy match. Records default to be imported, but you can either
click Select/Deselect All,
or click the Import check
box to individually select/deselect records to import. Imported records
will only be updated based on the Matched Record Behavior defined
in the Prospect/Student Import Parameters.
- Click Next
on the Fuzzy Matched Records window to continue to the Stored Procedures window.
If your institution has created stored procedures to be applied, define
those here. If not, click Next
to continue to the Review and Process
window.
Note: There are 2 parameters that are required if you want to run a stored proc during the import process(either before or after), @UserName and @JobID --- in that order. @UserName is varchar(15) and @JobID is int. Knowing @JobID you will be able to do anything that you need to do.
If you are attempting to do something with an "after" stored proc, here is more info that will be helpful. The 2 tables you are interested in are CAMSImportGeneric and CAMSImportGenericMatch. CAMSImportGeneric.JobID is the JobID that will be passed as the parameter. CAMSImportGeneric and CAMSImportGenericMatch are linked by the column CAMSImportGenericUID.
If CAMSImportGenericMatch.Import = 1, then that row was selected for import. If it is = 0 then this record was skipped during the import. CAMSImportGenericMatch.SelectedRecordType will either be 'Prospect' or 'Student' - this will obviously tell you if the the record created/updated a student or prospect record.
CAMSImportGenericMatch.SelectedUID will either be ProspectID or StudentUID depending on CAMSImportGenericMatch.SelectedRecordType.
CAMSImportGenericMatch.SelectedUpdateType will either be 'Existing' or 'New'. If the value is 'Existing' it updated a prospect or student, if it is 'New' it created a prospect or student record.
- Review all records to be imported,
and if satisfied with the data, click Finish
to complete the Prospect/Student Import process. The Messages
window displays with an Import Is Complete confirmation. Aside from
the confirmation message, the Messages window is reserved for future
functionality.
- The Messages
window displays with an Import Is
Complete confirmation. An example message may be that the SSN
already existed in CAMS so this Prospect or Student was imported without
an SSN if the user elected to import the Prospect or Student as is.
- Click Email
to send new Prospects or Students (not Fuzzy or Exact matches) can
be emailed with the message of your choice. Portal Login User and
Password can be included in the email by highlighting them from the
special fields section then right-click and choose paste to insert
the field into the message.
Related Topics